Resources Selection Guide: Streptavidin Probes for Biotin Tag Capture A quick reference to match each probe to analyte size, sample type, and assay needs Biotin-streptavidin capture is one of the strongest non-covalent interactions available for BLI, but a single streptavidin (SA) chemistry doesn’t serve every assay well. Analyte size, sample complexity, and whether you need to reuse the surface across multiple ligands all require different biosensor properties. Gator® Bio offers five streptavidin biosensor options: three single-use probes (SA, SA XT, SMAP) and two reusable kits (Flex SA, Regen SA). Surface properties and optical performance of each probe are tailored for different assay needs. Running more than one probe type during method development can unlock improved performance for your specific assay. Access the full details and recommendations by downloading the Selection Guide PDF: Download Selection Guide Choosing by analyte size Analyte size is one of the first filters to apply. The figure and table below maps common analyte sizes and types to the probes worth evaluating first. Figure 1. Recommended analyte molecular weight ranges for different streptavidin biosensor probes offered by Gator Bio. Analyte TypeRecommended Probes to EvaluateSmall molecules ≥ 150 DaSMAPOligomers/peptides ≥ 1.5 kDaSMAP, SA XT, Regen SAProteins/antibodies 15 – 150 kDaSA, SA XT, Flex SA, Regen SALNPs, VLPs, large complexes ≤ 2 MDaSA XT Table 1: Recommended streptavidin probe options to evaluate for common analyte types and size ranges. SMAP is the only probe built specifically for small molecules. SA XT is the one chemistry that spans the highest range, from 1.5 kDa oligomers up to 2 MDa complexes like LNPs and VLPs. For standard 15–150 kDa protein and antibody work, SA, SA XT, Flex SA, and Regen SA all apply. Which of the four you pick from there comes down to reuse needs and sample complexity, covered below. Probe details SA ProbesSA captures biotinylated proteins across the standard 15 – 150 kDa range and is built for crude samples, including serum and lysates. It delivers the best precision of CV ≤ 6 % within-tray for most sample types, with reproducible kinetics. SA XT ProbesSA XT pairs its streptavidin surface with a design that reduces mass transport effects from very large analytes, giving it a recommended molecular weight range of up to 2 MDa. Built on Gator’s XT Optics technology, this probe adds up to 3x signal-to-noise over SA probes allowing it to confidently resolve kinetics of analytes down to 1.5 kDa. SMAP ProbesSmall Molecule Analysis Probes (SMAP) combine a high-density streptavidin surface with XT Optics to extend detection down to small molecular weight analytes, and are well suited to small molecule and peptide kinetics. Flex SA ProbesFlex SA is a reusable kit that strips and reactivates the streptavidin layer between experiments, giving you a clean surface for each assay. It’s built for repeated experiments with crude samples or moderate-throughput biotinylated protein screening in the 15–150 kDa range, and regenerates 10+ times. Regen SA (RSA) ProbesRegen SA (RSA) uses an engineered streptavidin surface that regenerates with a standard protocol with the kit’s proprietary regeneration solution. Built on XT Optics, it is ideal for high-throughput screening of both low molecular weight analytes and larger proteins, regenerating up to 10 times. Because the engineered surface binds biotin less tightly than native streptavidin, Regen SA isn’t recommended for kinetic interactions with KD below 100 pM. Long biotin linkers improve capture performance; AviTags are not recommended for this probe. For more details and recommendations, download the full guide: Download Selection Guide FAQs What’s the difference between SA, SA XT, and SMAP streptavidin biosensors? All three are single-use probes. SA covers the standard 15–150 kDa protein and antibody range. SA XT extends that range from 1.5 kDa up to 2000 kDa, adding VLPs, LNPs, and nanodiscs. SMAP is built specifically for small molecules and peptides starting at 150 Da. Which streptavidin biosensor should I use for small molecules or peptides? SMAP is built for small molecular weight analytes and peptide kinetics. SA XT and Regen SA also cover oligomers and peptides down to 1.5 kDa. Which biosensor should I use for LNPs, VLPs, or other large complexes? SA XT is the recommended probe for large complexes up to 2 MDa, including LNPs, VLPs, and nanodiscs. What’s the difference between Flex SA and Regen SA? Both are reusable kits that regenerate. Flex SA strips and reactivates the streptavidin layer itself between runs and is built for crude samples or moderate-throughput screening in the 15–150 kDa range. Regen SA uses an engineered streptavidin surface that regenerates without removing the layer and offers up to 3x higher signal with XT Optics, though it isn’t recommended for kinetic interactions with KD below 100 pM. Can streptavidin biosensors be reused? Flex SA and Regen SA are both designed for repeated reuse, regenerating 10 or more times. SA, SA XT, and SMAP are single-use probes, though analyte-only removal is possible under sample-dependent conditions, leaving the ligand on the probe for reuse. Are AviTag-labeled proteins compatible with all streptavidin biosensors? AviTag is compatible with SA, SA XT, SMAP, and Flex SA. It is not recommended for Regen SA, as longer linkers provide better capture performance on the engineered streptavidin. Due to the compact nature of AviTags, some samples may experience steric hindrance of the biotin tag to the streptavidin capture surface resulting in some dissociation. If this occurs, using long linkers (eg. PEG4 or LC/LC-LC) can also improve capture on SA, SA XT, SMAP and Flex SA probes. What biotinylation linker works best for Regen SA probes? Long linkers such as LC-LC-Biotin, PEG4-Biotin, or biotin-dT are recommended for Regen SA for best capture performance. Get in touch Still not sure which probe fits your application? Get in touch with us at [email protected]. Shop now Find the right biosensors for your research. Explore the Gator Bio catalog and shop biosensors for your biolayer interferometry assays. Browse complete biosensor catalog
Resources Fc Receptor Assays Using Gator Bio HIS XT Biosensors Optimized BLI protocols for clean 1:1 IgG–FcγR binding kinetics ABSTRACT Fcγ receptors (FcγRs) mediate antibody effector functions, linking the antibody-target interaction to cellular cytotoxicity, phagocytosis, and inflammatory signaling. Engineering the IgG Fc region to modulate FcγR binding enables antibody engineers to make strategic decisions about whether their biomolecules enhance effector function, only function for certain receptors, or prevent effector activity entirely. Characterizing the interactions between IgG and the activating receptors CD64/FcγRI, CD32/FcγRII, and CD16/FcγRIII is therefore a routine and high-priority measurement across both discovery and development pipelines. Biolayer interferometry (BLI) is an ideal method for FcγR interaction screening because it offers real-time, label-free kinetic measurements with the throughput and sample efficiency required for iterative Fc engineering campaigns. However, FcγR assays present unique technical challenges that must be carefully addressed. Here we present optimized protocols for measuring IgG–FcγR kinetics on the Gator® platform for FcγRIIA, which can be applied to other Fc receptors as well. We highlight Gator Bio’s HIS XT biosensor as a preferred capture surface, as its improved sensitivity enables users to load far less onto the sensor surface, and the Fc-free capture molecule eliminates a key source of assay interference. We also provide practical setup guidance for users new to FcγR kinetics, addressing common pitfalls encountered when working with these receptors for the first time. Download Application Note INTRODUCTION What are Fc Receptors? Why are they commonly screened? Fc gamma receptors (FcγRs) are a family of cell-surface proteins expressed on a variety of lymphoid, myeloid, and non-immune cells that respond to immunoglobulin G (IgG), in order to drive appropriate responses to infections while being transient enough to avoid autoimmunity. The receptor family encompasses three major classes: the high-affinity FcγRI (CD64) and the low-affinity FcγRII (CD32) and FcγRIII (CD16), each with distinct cellular distributions and functions including phagocytosis, release of inflammatory mediators, or antibody-dependent cellular cytotoxicity. Beyond their roles in basic immunology, FcγRs are of critical importance in the development and optimization of therapeutic antibodies. Fc-mediated effector functions are essential for the therapeutic efficacy of many monoclonal antibodies (mAbs), while avoiding Fc receptor activation is essential for other biologics. Accurately characterizing these interactions across multiple receptor subtypes, IgG isotypes, and clinically relevant polymorphisms is therefore essential for researchers developing biosimilars, discovering therapeutics, studying immune-mediated disease, or engineering next-generation antibody formats. Bio-Layer Interferometry (BLI) for Fc Receptor binding characterization Bio-layer interferometry (BLI) is an optical, label-free biosensor method for real-time kinetic analyses and analyte quantitation high throughput. In a BLI experiment, the antibody or receptor of interest is immobilized on the tip of a pre-coated fiber-optic biosensor. When transferred to a well containing the binding partner of interest, shifts in the interference pattern of reflected white light are measured in real time, yielding the association rate (kon), dissociation rate (koff), and equilibrium dissociation constant (KD) directly from a single experiment. Critically, BLI requires no fluorescent or radioactive labeling, allowing researchers to study interactions in their native state. For Fc receptor binding characterization, BLI has emerged as a standard analytical tool [1, 2]. The United States Pharmacopeia has released general chapter <1108> (Assays to Evaluate Fc-Mediated Effector Function), which cites the use of bio-layer interferometry in key ligand binding applications, noting its ability to provide precise kinetic data and measure a relatively wide range of binding affinities. BLI-based FcγR binding assays have been shown to overcome interference from sample aggregates (generally, up to 5% [1]), distinguish different Fc Receptor polymorphisms [3, 4], and serve as stability-indicating methods suitable for drug product release and stability testing. Figure 1: Schematic of standard (top) and XT (bottom) biosensors and their resulting signal intensity. Gator XT Biosensors capture more light from the protein layer, resulting in a greater overall interference. This translates to a larger nm shift in the raw data, providing 3x or greater signal-per-molecule on the surface of the biosensor. HIS XT as the ideal capture surface for Fc Receptor interaction study Much of the publicly available BLI and SPR data online show sharply angled, distorted curves for the low-affinity Fc receptors FcγRII (CD32) and FcγRIII (CD16). These artifacts are often caused because an extremely low ligand loading step is required to visualize 1:1 binding kinetics during Fc receptor-antibody interaction, but classical anti-His biosensors use bivalent capture molecules (anti-His antibodies from rabbit or mouse), and lack sensitivity to visualize a low loading step. Moreover, clear protocols for performing these experiments are uncommon and often include poorly optimized conditions. In this application note, we will provide guidelines and give examples of Gator BLI data featuring FcγRIIA/CD32a (R167) performed in a manner that avoids these signal artifacts. In particular, this application note will use the new Gator HIS XT biosensor and take advantage of its two major improvements. The first major improvement is the use of an AI-derived capture molecule called a NovoBody™. This single-domain capture molecule, generated in partnership with Monod Bio, has high affinity and minimizes potential avidity and rebinding effects. Its XT surface captures more light reflected from the protein layer, increasing total signal per molecule. These two advantages make the Gator HIS XT biosensor the ideal choice for Fc receptor studies using BLI. MATERIALS AND METHODS Reagents and equipment ItemOriginSpecification / Part NumberGator® Pivot or Plus+Gator BioPN 110055BLI 384-Tilt Plate, PolypropyleneGator BioPN 130161Anti-His (HIS) XT ProbesGator BioPN 160050K BufferGator BioPN 120011Regen buffer (No salt, pH 2.0)Gator BioPN 120008AntibodyUser supplied–FcγRIIA/CD32a [R167]ACROBiosystemsCD0-M36A2 (see appendix 1) BLI Fcγ Receptor binding assay workflow The FcγR workflow is structured in a five-step process immobilizing a his-tagged Fc gamma receptor (in this case, FcγRIIA/CD32a [R167]), followed by antibody association as explained below. Immobilizing the FcγR is the ideal choice for this method because researchers typically have an excess of antibody on hand but only limited amounts of Fc receptor, and cannot afford to use micromolar amounts of Fc receptor as analyte. The HIS XT biosensor was selected for all experiments for reasons enumerated in the previous section. Unless otherwise noted, all steps were performed on a Gator® Pivot instrument at 30ºC, 400 RPM shaker speed at 10 Hz data acquisition rate. The reduction in shaker speed improves the quality of the signal during the beginning of both the association and dissociation phases by slowing the total collision rate, similar to how adjusting flow rate affects mass transport in SPR. Some experiments below were also performed on a Gator Plus+, which has improved temperature control, enabling experiments at 10ºC. Remarkably, this change does not introduce mass transport limitation at the tested flow rate regardless of assay temperature (Figure 6). For a visual overview of the full experiment, consult Figure 5. Step 1 – Biosensor equilibration and baseline Pre-wet HIS XT Biosensors in K Buffer for 600 seconds Instrument transfers biosensors to K Buffer “buffer” well Baseline time: 120 seconds Step 2 – FcγR immobilization Instrument transfers biosensors into FcγR well Association time: 20 seconds (adjust depending on expected titer) FcγR recommended concentration: 0.3 µg/mL Step 3 – Second baseline Instrument transfers IgG-loaded biosensors to K buffer “blank” well Second Baseline time: 60 seconds Step 4 – Antibody association Instrument transfers IgG-loaded biosensors to a series of wells containing the antibody of interest beginning at 2.5 µM in a twofold serial dilution in K buffer Association time: 60-120 seconds Step 5 – Antibody dissociation Instrument transfers biosensors to well containing only K Buffer to observe antibody dissociation. Dissociation time: 60-120 seconds Biosensor regeneration Instrument transfers biosensors between Regen Buffer (no salt, pH 2.0) and K buffer 3-5 times in 5-second pulses HIS XT Biosensors can typically be reused for 10 or more cycles with <15% signal loss (see Appendix 2) Note: Optimization of regeneration conditions should be performed when working with unusual supernatant conditions, Fc receptor variants, or antibody constructs. Figure 2: schematic representation of probe surface at each step of Fc receptor kinetics experiment. Calculating interaction affinity Unless otherwise noted, assays were analyzed using the following parameters in the GatorOne analysis software: Align to association, average 0 Inter-step correction: On Averaging range set to 0 for both association and dissociation Single reference subtraction using loaded biosensor interacting with buffer blank Note: double-reference subtraction may be required when using a low-quality antibody sample – see appendix 1 for details on how we determined the ideal antibody for use in these example assays, along with advice for reducing NSB using His-Ubiquitin should NSB persist. Fitted using a 1:1 Langmuir fitting model. RESULTS AND DISCUSSION Fc Receptors do not bind to HIS XT Biosensors as analytes A key question is whether FcγRs bind non-specifically to the HIS XT biosensor – if they do, any dissociation from the biosensor surface must be allowed to complete in a second baseline step before introduction of antibody analytes. Figure 3 shows that non-his-tagged FcγRIIA/CD32a (R167) does not interact with the sensor surface in any detectable way at concentrations up to 10 µg/mL, the highest concentration tested. This confirms that the single-domain NovoBody™ design on the surface of the biosensor does not contain an Fc or similar off-target binding site. Identifying appropriate Fc receptor load on HIS XT Figure 4 shows a loading experiment with titered 6xHis-tagged Human FcγRIIA/CD32a (R167) ligand loading step, showcasing how at higher ligand loads, both association and dissociation rates are altered due to mass transport limitation, and the dissociation trace does not approach zero as a result of rebinding. High-load samples (red, yellow, green) take 30 seconds or more to reach complete analyte association; low-load samples (purple, magenta) reach the same endpoint in under 10 seconds. During dissociation on high-load samples, dissociation does not approach zero. This is caused by a rebinding effect, where antibody is unable to adequately dissociate from the sensor surface because the probability to encounter and bind to another CD32 is higher. In contrast, a load height of 0.5 nm (from purple trace, using 0.3125 ug/mL FcγRIIA/CD32a (R167) or ~10 nM) resulted in binding curves that produced a 1:1 interaction and which dissociate to zero. This represents loading to approximately 8% of maximum load height on HIS XT biosensors, which have a maximum capacity around 6.5 nm shift for this particular CD32 variant, whereas typical anti-His sensors have 2 nm or less. This increase in nm shift capacity is not due to an increase in total number of binding sites, but is instead an optical change from the XT optical improvements, which captures more of the light reflection from the protein layer, resulting in greater interference and measurable nm shift. In practice, this change results in a ~3x increase in total overall signal for the same protein density on the sensor surface – a 0.5 nm shift on a HIS XT biosensor has approximately the same density of captured molecules as a traditional anti-His biosensor loaded to between 0.125 and 0.167 nm shift. With less overall protein loaded onto the HIS XT surface, mass transport and rebinding are less problematic, but sensitivity remains clear. Further experiments in this application note use this loading concentration (0.3 µg/mL, 20 seconds load, 400 RPM shaker speed) and also use the GatorOne software feature to set a loading threshold of 0.5 nm, to prevent human error. Figure 3: TST-tagged (non-his tagged) Human FcγRIIA/CD32a (R167) at 10 µg/mL red), 5 µg/mL (yellow), and 2.5 µg/mL (green) against HIS XT biosensors. Figure 4: Effect of load height on Antibody binding to FcγRIIA/CD32a (R167). A: Full assay overview, with loading heights ranging from 0.2-3.5 nm shift, each interacting with Rituximab at 625 nM as analyte. B: magnification of association and dissociation steps all setting beginning of association step to 0. FcγRIIA-Antibody kinetics show a 1:1 binding curve After loading height normalization to 0.5 nm shift, antibodies were titrated from 2500-125 nM to ascertain the interaction affinity constant, KD. As expected, some minor non-specific binding of antibody to the biosensor surface was observed representing less than 10% of the total overall response. This is not just specific to the HIS XT biosensor – a change in refractive index due to high Ab concentration as well as antibody NSB to the surface at concentrations greater than 1000 nM are both possible [4]. To mitigate this issue, we elected to use double-reference subtraction with an unloaded biosensor as reference. Example of these traces is contained in Figure 5. Kinetics results agree with established literature, which places the KD for the CD32-IgG1 between 0.5 and 2.5 µM. Moreover, the curves show well-resolved association kinetics, approaching saturation rather than plateauing immediately, giving greater context to on- and off-rate fitting. Average Load height (nm shift)0.51KD (M)1.05 µMkoff (s-1)1.26*10-1kon (M-1 s-1)1.2*105R20.99X23.68 Figure 5: Rituximab (analyte) interacting with his-Human FcγRIIA/CD32a (R167) (ligand) on HIS XT biosensors. Biosensors were loaded to ~0.5 nm shift, after which these results were collected. Results are aligned to beginning of association step and double-reference subtracted. Kinetics results are shown in the table and align with experimental data on supplier’s website for the interaction (1.4 µM on competitor BLI; 2.3 µM on SPR). Temperature-dependent kinetics of FcγRIIA/CD32a are consistent with established literature Assays performed across different temperatures showed small deviations in overall KD as a result of assay temperature which align with previously-established kinetics values measured by SPR [5]. Importantly, the on-rate remains largely steady among the assay temperatures tested, while koff is dramatically affected by temperature. From a practical assay design perspective, this means that Gator BLI using HIS XT provides kinetics results that align with other techniques regardless of temperature, allowing users flexibility in choosing assay temperatures depending on experimental needs. Often, lower temperatures are used to slow the binding interaction for accurate curve fitting, and these data support that changing temperature does not introduce any unusual variation to the kinetics, with R2 values consistently above 0.99 (see Figure 6). 10°C25°C40°CKD (M)1.56*10-74.74*10-71.21*10-6kon (M-1s-1)1.05*1051.36*1051.17*105koff (s-1)1.64*10-26.46*10-21.42*10-1R20.99250.99560.9966 Kinetics report table Figure 6: Fc receptor assays run at different temperatures on the Gator HIS XT biosensor at 0.5 nm shift and 400 RPM shaker speed. Even at 40°C, the assay provides a clean 1:1 fitting, highlighting how HIS XT improvements to sensitivity and monovalent capture provide dramatically improved data quality when following the protocol outlined above. CONCLUSION The data presented here demonstrate that the Gator HIS XT biosensor provides a robust and reliable platform for characterizing IgG–FcγR interactions using BLI. By combining an XT optical surface with a single-domain capture molecule, the HIS XT biosensor enables low-density receptor loading that produces clean 1:1 binding kinetics for low-affinity receptors such as FcγRIIA/CD32a – an outcome that has historically been difficult to achieve with conventional anti-His biosensors. The optimized protocol presented here, including loading normalization to 0.5 nm and double-reference subtraction to address non-specific antibody binding at high concentrations, consistently yields well-resolved association and dissociation curves with R² values above 0.99. Temperature-dependent kinetic measurements further confirmed that the HIS XT platform produces results consistent with established SPR literature values, with koff responding predictably to temperature while kon remains stable, giving users flexibility to adjust assay conditions without compromising data quality. These characteristics position the Gator HIS XT biosensor as a practical path to compliance with USP general chapter <1108> (Assays to Evaluate Fc-Mediated Effector Function), which cites BLI as a reference method for Fc receptor binding characterization. The protocols and best practices outlined here are directly applicable to FcγRIIIa/CD16a assay development, where the same low-affinity binding challenges and sensitivity requirements apply. The HIS XT biosensors are also re-usable (See Appendix 2), making them the ideal choice for high throughput screening for iterative Fc engineering workflows. Download Application Note WORKS CITED A. Bajardi-Taccioli, C. Co, C. Bond, A. Masci, T. Brantley, C. Xu, S. Bergelson and M. Feschenko, “Biolayer Interferometry-based FcγRIIa binding assay for a therapeutic antibody with strong effector function,” Analytical Biochemistry, vol. 611, 2020. BPS Bioscience, “Protein Binding Studies / BLI Detection Services,” [Online]. Available: https://bpsbioscience.com/label-free-bli-detection-services. [Accessed 2026]. J. D. Twomey, S. George and B. Zhang, “Fc gamma receptor polymorphisms in antibody therapy: implications for bioassay development to enhance product quality,” Antibody Therapeutics, vol. 8, no. 2, pp. 87-98, 2025. Gator Bio, Inc., “Optimizing BLI Assays: Effective Strategies for Reducing Non-Specific Binding,” 19 Mar 2026. [Online]. Available: https://www.gatorbio.com/resources/optimizing-bli-assays-effective-strategies-for-reducing-non-specific-binding/. P. Katsumi Maenaka, A. van der Merwe, D. I. Stuart, E. Y. Jones and P. Sondermann, “The Human Low Affinity Fcγ Receptors IIa, IIb, and III Bind IgG with Fast Kinetics and Distinct Thermodynamic Properties,” Journal of Biological Chemistry, vol. 276, no. 48, pp. 44898-44904, 2001. Appendix 1: Troubleshooting Fc Receptor Assays (including Figure 7) is available in the full PDF version of this application note. Download the application note to view it. Appendix 2: Reproducibility after regeneration on HIS XT Robustness of the regenerable surface and the ability to completely release captured Fc receptor ligand are equally important. To confirm that Fc receptor is completely removed after loading, we performed an Fc receptor binding experiment ten times with the same biosensor, then skipped the Fc receptor load step to directly expose the sensor to the antibody. The premise is that if the antibody bound, it would indicate that the Fc receptor had not been completely removed from the surface, most likely due to incomplete regeneration. Our result (Figure 8) indicates that the HIS XT biosensor completely releases bound Fc receptor from the sensor surface using the standard Regen Buffer (No Salt, pH 2.0) as recommended in this protocol. After these repeated assays, the sensor surface showed near-zero NSB from antibody at 2.5 µM. Figure 8: Regeneration efficacy of Fc receptor/antibody interaction study using HIS XT. Top: Raw data from CD32 capture and Rituximab binding across ten studies. Bottom: Rituximab signal after 10x regenerations with no ligand loaded – demonstrating that PN: 120008 Regen Buffer pH 2.0 causes complete removal of bound CD32a even after 10 cycles.
Resources Closing the Loop SF 2026: A gathering on the AI-native lab – Session Recordings Access Event Recordings Event Title: Closing the Loop SF 2026 — On-Demand Event RecordingsRecording Date: June 5, 2026 On June 5 in South San Francisco, five organizations showed what it looks like when computational protein design and wet lab validation are no longer separate steps. Every talk came back to the same thing: the gap between what the model predicts and what the experiment returns is closing. Fast. Sessions: The New Way Biologists Work — Kexin Huang, PhD, Co-founder, Phylo Designing Functional Proteins With Artificial Intelligence — Sharrol Bachas, PhD, Founder & CSO, Onava Closing the Loop: Ultra-Fast Wet Lab Validation for AI-Guided Protein Design — Ron Gill, PhD, Innovation Manager, Adaptyv Bio AI-Designed Biosensors on Gator — Daniel-Adriano Silva, PhD, CEO and President, Monod Bio Gator Bio Technology Review — Sriram Kumaraswamy, PhD, VP of Marketing & Product Management, Gator Bio Welcome & Framing: Hong Tan, Gator BioHosted by: Gator Bio
Resources MFC XT Biosensors for Hybridoma Screening Quantitation, off-rate ranking, and clone triage from crude supernatants in a single BLI run ABSTRACT Hybridoma panels remain a cornerstone of therapeutic and research antibody generation. Hybridoma screening requires the rapid assessment of hundreds to thousands of clones for secretion, titer, and binding characteristics. At this scale, traditional ELISA-based workflows are stifled by significant manual burden and provide no straightforward path to early exclusion of poor binders. This application note demonstrates how Gator® Anti-Mouse IgG Fc (MFC) XT Biosensors enable quantitation, off-rate ranking, and affinity-based candidate triage in a single automated Biolayer Interferometry (BLI) run. Compared to typical BLI biosensors, MFC XT Biosensors offer superior per-molecule signal resolution, a broad dynamic range of 0.02–10,000 µg/mL, and robust regeneration for up to 20 cycles. Practical guidelines for implementing this workflow, including candidate ranking strategies and clone exclusion criteria, are covered in detail. Download Application Note INTRODUCTION The hybridoma screening challenge Although artificial intelligence and display library screening have taken much of the spotlight for their speed, they lack many advantages of mouse hybridoma screening methodology, such as: Antibodies derived from hybridomas undergo in vivo affinity maturation, producing candidates with refined selectivity profiles that naïve display library methods typically cannot replicate without additional directed evolution steps. Hybridoma-derived antibodies are generated through natural B cell development, meaning they tend to exhibit favorable biophysical properties such as reduced propensity for aggregation and greater thermal stability compared to many display library-derived candidates. In vivo immunization with intact or membrane-embedded antigens enables the generation of antibodies against difficult target classes including GPCRs, ion channels, and heavily glycosylated proteins that remain challenging for both computational design and display library approaches. Following the early steps of cell fusion and HAT isolation, successful campaigns routinely yield hundreds or thousands of clones, none of which are purified at the screening stage. The most common approach to hybridoma screening at this scale is to use ELISA, which is scalable, but only provides endpoint data, and is prone to poor intra- and inter-assay reproducibility (%CV). Biolayer Interferometry (BLI) addresses these limitations by delivering reproducible real-time interaction data directly from crude hybridoma supernatants without requiring sample purification. BLI is commonly used in hybridoma screening for: Measuring IgG secretion and approximate titer Ranking candidates based on dissociation rate (koff) Cross-reactivity and epitope group assignment HOW BLI WORKS BLI measures changes in the interference pattern of white light reflected from the surface of a biosensor probe. As molecules bind to or dissociate from the probe tip, the optical path length changes, producing a measurable shift in the interference spectrum (measured as nm shift). Since the signal depends only on molecules at the probe surface, BLI is highly tolerant of matrix effects from crude cell culture media when proper experimental steps are taken to limit these effects (Appendix 2). MATERIALS AND METHODS Reagents and equipment ItemOriginSpecification / Part NumberGator® PlusGator BioPN 110022BLI 384-Tilt Plate, PolypropyleneGator BioPN 130161MFC XT ProbesGator BioPN 160049Q BufferGator BioPN 120008Regen buffer (No salt)Gator BioPN 120063Mouse IgG standardUser suppliedTarget antigenUser suppliedHybridoma supernatantsUser supplied Biosensor selection The Gator MFC XT Probe is a next-generation anti-mouse IgG Fc capture biosensor engineered to outperform first-generation Mouse Fc biosensors in hybridoma workflows and other kinetics applications. Key design improvements over first-generation MFC biosensors include: Greater signal-per-molecule using Gator’s proprietary XT optical coating Broader dynamic range enables quantitation without dramatic pre-dilution across the range of typical hybridoma titers Monomeric capture molecule, reducing incidence of avidity for kinetics applications High subclass coverage: IgG1, IgG2a, IgG2b, and IgG3 High specificity for mouse IgG with low cross-reactivity to other IgG species Robust regeneration chemistry supporting up to 20 cycles per probe Assay workflow overview The MFC XT hybridoma screening workflow is structured in a five-step process enabling first-pass quantitation and off-rate ranking with a single re-usable biosensor. Step 1 – Biosensor equilibration and baseline Pre-wet MFC XT biosensors in Q buffer for 10 minutes Instrument transfers biosensors to Q buffer well for 60 seconds to measure baseline prior to sample loading Step 2 – Mouse IgG capture and quantitation Instrument transfers biosensors into hybridoma supernatant wells (diluted 1:1 in Q buffer to reduce matrix effects and signal deviations while maintaining detectable signal) Association time: 300 seconds (adjust depending on expected titer) Step 3 – Second Baseline Instrument transfers IgG-loaded biosensors to buffer blank well Second Baseline time: 60 seconds Note: if second baseline loses more than 20% of its signal after loading, it is likely to be non-specific binding from the matrix dissociating from the sensor. Consider increasing dilution or extending second baseline to ensure a flatter baseline for the association/dissociation steps. Step 4 – Antigen association Instrument transfers IgG-loaded biosensors to wells containing a single concentration of antigen (diluted in Q buffer) Antigen concentration: 500 nM Association time: 180 seconds Note: At least one ligand well (step 2) should be a blank or similar negative control to detect non-specific signal as a result of direct antigen binding to the biosensor or refractive index changes from solvents in the antigen wells (e.g. DMSO, Glycerol, Sucrose, etc.) Note: Antigen concentration assumes a naïve panel. For panels with a stronger expected affinity, a lower concentration can be used to better discriminate candidates. Figure 1: Five-step BLI hybridoma screening workflow: 1) probe equilibration and baseline, 2) mouse IgG capture from crude supernatant, 3) second baseline, 4) antigen association, 5) dissociation. Step 5 – Antigen dissociation Instrument transfers biosensors to a well containing only Q buffer Dissociation: 180+ seconds in Q buffer to characterize koff (dissociation rate) Note: Adjust time depending on quality of the panel – early panels can be screened in 180 seconds (faster koff); panels that have undergone affinity maturation may need 600 seconds or more. Biosensor regeneration Instrument transfers biosensors between Regen Buffer (No Salt) and Q buffer 3-5 times in 5-second pulses Biosensors can typically be reused for up to 20 cycles with <15% signal loss (see Appendix 1) Note: Optimization of regeneration conditions should be performed when working with unusual supernatant conditions or antibody constructs Identifying concentration from screening data Using GatorOne kinetics analysis software under 3: Set Reference, select the loading step on the graph and use “Quantitate” to enable quantitation mode. Signal (nm) read against previously-measured 7-point mouse IgG standard curve (0.02-1.28 µg/mL) with blank subtracted. Candidate ranking Exclusion criteria When association responses are weak or absent, kinetics fitting software may return artifactually low koff values, since dissociation cannot be meaningfully measured in the absence of a real binding signal. Exclusion criteria prevent these false positives from advancing. Clones with loading response below 0.2 nm (< 0.20 µg/mL final concentration) or with atypical loading curves can be flagged as non-secretors (or IgM secretors if they still show antigen binding). Note: This cutoff is empirically derived and specific to the MFC XT biosensor and mouse antibody panels — individual adaptation may be required. Samples with bound Ab showing poor antigen binding are classified as non-binders and excluded. Many users classify poor binders based on absolute antigen binding response, and this is a valid approach, but it ignores variability in antibody loading across clones. In this case, individual clone antigen:load ratios are compared to the panel’s average ratio – candidates whose ratio is ½ the panel’s average are excluded as poor binders. Note: All exclusion criteria are arbitrary. This method simply gives a rational approach for comparing binding efficacy across different hybridomas. This cutoff can be adjusted to be more or less stringent depending on the nature of the panel. Candidate ranking Single-concentration kinetics results are fitted with GatorOne software using a 1:1 model. Remaining binders ranked by koff (dissociation rate) for rapid lead prioritization. Lead clones identified by off-rate ranking proceed to a full kinetics assay in a follow-up experiment. While users often perform screening experiments with unpurified antibodies, a multi-concentration kinetics assay is typically performed using purified antibodies. Selected antibodies are exposed to a 5-7 point serial dilution of antigen (typically starting 20x above the estimated KD from screening and diluting twofold per point) alongside controls (e.g. zero antigen blank). Kinetics values (kon, koff, and KD) are calculated by global 1:1 Langmuir fitting in GatorOne software. RESULTS AND DISCUSSION Quantitation of Mouse IgG on the MFC XT Biosensor 96 antibodies from the hybridoma panel were compared to a standard curve of mouse IgG for concentration determination. The standard curve is provided below in Figure 2. Note: The Gator MFC XT biosensor can be used to detect a higher range of antibodies for quantitation. To obtain higher-titer results up to 10,000 µg/mL, an experiment at 25ºC and at 400 RPM for 10-30 seconds is appropriate. Figure 2: Quantitation standard curve. A: Assay parameters and results of standard curve for mouse IgG. B: Appearance of raw sensorgrams at the indicated assay parameters and concentrations. C: Standard curve output using initial binding rate (nm/sec) using a linear regression for fitting. CANDIDATE RANKING AND EXCLUSION A selection of 48 out of 96 tested samples is shown in Figure 3 and identified with a grid system. Of these 48, the following were excluded based on selection criteria outlined in methods section: Insufficient loading response (Loading step not shown) Cutoff set to 0.2 nm load (see methods) Newly excluded: A4, B5, B6, C5, C6, E3, F1, G4, H2, H4 Note: kinetics software returned an artifactually low koff value for E3 and H4. This is an example of how filters can help weed out deceptive fitting results. Poor response-to-load The average antigen binding response was 76% of antibody loading response. Load:Antigen ratios lower than 38% ( ½ of panel average of 76%) are classified as low/poor binders (or IgM secretors) Newly excluded: A6, B2 Candidates that were not eliminated based on these criteria were ranked on koff values. The top five candidates from this selection of 48 are given below. Note: koff values lower than 1.00*10-6 s-1 are typically considered out-of-range for BLI. However, none of these values should be considered definitive at this stage – they should only be used for ranking candidates at this stage, given that the dissociation time is only 180 seconds. D6 koff: <1.00*10-6 s-1 G2 koff: <1.00*10-6 s-1 D2 koff: 6.20*10-5 s-1 D1 koff: 1.32*10-4 s-1 E2 koff: 1.77*10-4 s-1 These five candidates, selected purely on the basis of off-rate ranking from crude supernatant, represent the output of a complete first-pass screen and are well-positioned for definitive KD determination in a multi-concentration kinetics assay. Note: Accurate kinetics values cannot be obtained with a single data point, particularly one at 500 nM, since the KD for these top five candidates is likely 1 nM or below based on the koff rates shown. As such, a good high-concentration starting point for the titration series used in the kinetics assay would be 20-50x above the predicted KD from these experiments. Figure 3: 48 representative traces from a 96-sample hybridoma screen presented in grid format for reference. Colored traces indicate binders; excluded clones are identified by grid position. CONCLUSION Because hybridoma screening practices vary widely between laboratories and many workflows remain unpublished, reproducible and well-documented protocols are particularly valuable in this field. Applying the techniques covered in this application note enables users to obtain consistent, high-quality results when performing mouse hybridoma screening. Moreover, as demonstrated herein, MFC XT Biosensors address the primary bottlenecks in hybridoma screening workflows: Sensitivity at low titers alongside rapid loading response improving throughput for large clone sets. Expanded dynamic range (0.02–10,000 µg/mL) eliminates the pre-dilution step required with first-generation biosensors for high-titer clones, a common source of quantitation error and workflow interruption. Stable performance through multiple regeneration cycles (Appendix 1) as well as strong performance across a variety of media conditions (Appendix 2), making them an easy-to-deploy tool for any hybridoma laboratory and significantly reducing per-assay cost for high-throughput antibody characterization workflows. Download Application Note ADDITIONAL RESOURCES Lad et al. “High-Throughput Kinetic Screening of Hybridomas to Identify High-Affinity Antibodies Using Bio-Layer Interferometry,” SLAS Discovery, 20(4): 498-507, 2015. Säfsten P, Klakamp SL, Drake AW, Karlsson R, Myszka DG, “Screening antibody-antigen interactions in parallel using Biacore A100,” Analytical Biochemistry, 353(2):181-190, 2006. Ylera et al. “Off-Rate Screening for Selection of High-Affinity Anti-Drug Antibodies,” Analytical Biochemistry, 441(2), 2013. Table 1: Regeneration efficacy after 20 cycles at varying load densities. APPENDIX 1: Confirmation of regeneration efficacy Regeneration efficacy is typically measured by examining the total loading response after 30 seconds loading from the same antibody sample across cycles. In the figure above, we examined the re-usability of the biosensors after 20 cycles of regeneration using Regen Buffer (No Salt) for regeneration buffer and Q Buffer for neutralization buffer. Response is generated using the same antibody sample for each cycle for 30 seconds. As an additional confirmation of regeneration efficacy, the regenerated surface could also be re-tested with the antigen to determine whether antibody remains bound to the surface. Absence of binding (<0.01 nm in 30 seconds) confirms successful removal of captured antibody and readiness for reuse. APPENDIX 2: Preventing non-specific binding (NSB) to mouse hybridoma supernatants A common concern when working with hybridoma supernatants and other complex media is non-specific binding. The extent of NSB from each of these media onto the MFC XT biosensor surface was evaluated as shown in Figure 4A. Pre-wetting biosensors in a sample with the same composition (“matched pre-wet”) substantially reduced these non-specific binding responses, as shown in figure 4B. Diluting samples 1:1 in Q buffer provides an additional reduction in NSB and is recommended as a standard practice regardless of media composition. Figure 4: Reduction of non-specific binding from a variety of complex media by pre-wetting in matching media for ten minutes before the assay.
Resources On-Demand Webinar: From AI design to validated binder – closing the loop with reversible BLI biosensors Webinar Title: From AI design to validated binder – closing the loop with reversible BLI biosensorsRecording Date: May 6, 2026 Affinity-based protein analysis is entering a new era. As researchers push toward higher-throughput discovery, traditional tools often create bottlenecks that slow innovation. In this webinar you will learn: How Adaptyv Bio’s automated “protein foundry” accelerates validation through end-to-end workflow integration. Functional differences between streptavidin, Strep-Tactin, and Strep-Tactin XT. How the Strep-Tactin XT and Twin-Strep-tag pairing enables stable, reversible binding for efficient BLI sensor regeneration. Methods for combining advanced affinity technologies with automated platforms to enhance speed and scale. Host: SelectScienceCo-Host: Gator Bio Speakers:Ron Gill, Ph.D, Innovation Manager, Adaptyv BioDr. Alexandra Nordlohne, Product Manager, Cube BiotechBen Osborn, Ph.D, Product Manger, Applications, Gator Bio Moderator:Olivia Long, Pharma and Applied Science Assistant Editor, Select Science
Resources Optimizing BLI Assays: Effective Strategies for Reducing Non-Specific Binding How to identify, measure and reduce non-specific binding in BLI assays ABSTRACT Label-free detection technologies do not inherently distinguish between wanted signal and unwanted signal as any binding event on the surface of the sensor changes the optical density and becomes detected. This effect, known as non-specific binding (NSB), is a common challenge in biolayer interferometry (BLI) and other biochemical assays that compromise accurate kinetic and quantitative measurements through signal caused by unanticipated components of the sample buffer. NSB occurs when molecules in a sample including proteins, nucleic acids, lipids, or other biomolecules that bind unintentionally to unblocked regions of the biosensor surface rather than to the immobilized ligand. Incomplete surface blocking can promote hydrophobic and/or electrostatic interactions between sample components and the sensor, leading to elevated baselines, false association signals, and poor reproducibility. These effects are particularly pronounced when working with partially purified proteins or complex samples such as cell culture supernatants and crude lysates. NSB can occur across all types of BLI biosensors. This application note focuses on examples of NSB observed with Streptavidin (SA) biosensors and offers effective solutions to minimize NSB across a broad range of sample types, including purified biomolecules and complex matrices such as mammalian cell culture and E. coli crude lysates. By reducing off-target interactions, proper blocking methods improve assay accuracy, sensitivity, and overall data quality. Download Application Note INTRODUCTION BLI enables real-time, label-free analysis of biomolecular interactions, but assay performance can be adversely affected by NSB [1]. Similar to ELISA assays, where unblocked microplate surfaces can bind biomolecules and generate background signals, unblocked regions of a BLI biosensor can also contribute to NSB. Many BLI users assume that BLI biosensors are inherently specific and will interact only with the intended ligand or analyte. Consequently, a simple buffer (e.g., PBS) without the inclusion of a blocking agent is used for biosensor prewetting and sample dilution, as illustrated in Figure 1A. In practice, BLI biosensors are made of many layers, starting from glass to polysaccharide to streptavidin to capture ligands. Each of these various layers can contain exposed surfaces that are susceptible to non-specific interactions. Biomolecules present in sample buffers or crude matrices can bind to these exposed surfaces, resulting in significant NSB (Figure 1B). In BLI, NSB presents as an unusually high %CV in quantitation assays, an overestimation of the final result, a loss of signal across replicates or, in rare cases, a reduction of total binding signal. The goal of this application note is to provide tools to assess the total NSB present in samples and give clear guidelines for common troubleshooting approaches. Proper blocking (providing a molecule that binds to these spaces and ensures it’s always present in experimental solutions) can significantly improve data accuracy, reproducibility, and reliability when working with purified or crude biological samples. Figure 1: A. Expected Condition. B. Actual Condition. C. Blocked Condition. COMMON NSB BLOCKING AGENTS To mitigate NSB, we strongly recommend pre-blocking biosensors in conditions similar to the samples, and/or diluting protein samples in buffers containing one or more suitable blocking agents [2]. With effective blocking, NSB can be reduced to the point that true binding signals can be measured accurately and reliably (Figure 1C). Examples of successful blocking can be found in later sections. When performing BLI assays, blocking agents can take a variety of forms. The most common non-specific blocking agents are: Bovine Serum Albumin (BSA) – typically used at 0.02% to 5% of solvent Detergents like Tween20 – suitable up to 3% (Triton and SDS are not recommended) Sucrose – typically 0.1-0.6 M Imidazole – typically 5-20 mM (very useful for NSB related to anti-His or Ni-NTA biosensors) Higher salt (increased ionic strength can limit charge-based interactions) Additional NSB blocking agents have been shown to work for specific circumstances. For more information about potential blocking agents specific to your workflow, contact our support team. In addition to these non-specific binding agents, specific blocking also plays a role in limiting signal from certain analytes. Biocytin (a soluble biotin analogue used as a specific blocking agent) and other biotin blocking agents can help to prevent interactions with Streptavidin. Blocking with biocytin after ligand loading can help to prevent NSB of analyte molecules that have hydrophobic motifs that interact with the hydrophobic pocket of the biotin binding site, or for analytes that are biotinylated. Biocytin can also be used in place of ligand loading to identify the extent of non-specific interactions that are occurring between the sensor surface and the molecules of interest by preventing all interactions with the streptavidin binding site. Figure 2A shows the extent of non-specific binding that is caused by a biotinylated antibody – showing that a significant percentage (almost 20%) of all binding signal on the streptavidin biosensor is caused by protein interacting with non-streptavidin surfaces. This is further demonstrated in Figure 2B, wherein non-biotinylated PD-1 is able to bind non-specifically to the sensor in the unloaded biosensor conditions. Note that blocking with biocytin does not block PD-1 NSB – this is caused by interaction with the sensor surface and not the streptavidin itself. For reference, while the experiments in this paper used biocytin at 10 µg/mL without ligand loading, a typical protocol can also incorporate a 60 second blocking step (at the same concentration) after ligand loading to prevent a biotinylated analyte from interacting with Streptavidin. Figure 2 (A): Effect of biocytin blocking on biotinylated anti-PD-1 on SA biosensor. Note that approximately 18% of the total binding signal of biotinylated anti-PD-1 to the sensor was caused from interactions not associated with the Streptavidin-Biotin interaction. (B) Biotinylated anti-PD-1 (purple) or control (blue) are loaded onto SA biosensors and allowed to interact with either PD-1 or control well. PD-1 is not biotinylated – all binding signal here is non-specific interactions with the sensor surface. However, only the loaded biosensors dissociate to baseline after PD-1 interaction because anti-PD-1 provides adequate blocking of the biosensor, preventing PD-1 NSB. NON-SPECIFIC SIGNAL FROM REFRACTIVE INDEX CHANGES OR THROUGH DISSOCIATION OF BLOCKING AGENTS While this application note focuses on non-specific interaction between ligand or analyte molecules and the biosensor surface, one common source of non-specific signal is caused by transitioning biosensors between wells containing solutions with different refractive indexes. NSB from protein interacting with the sensor surface can coexist with non-specific signal from buffer changes, making it difficult to troubleshoot. The most common causes of these interactions include: Glycerol (remember, lyophilized proteins can still have glycerol in the powder) Detergents (e.g. Tween20) Changes in pH Sugars (e.g. Sucrose) Imidazole (particularly for anti-His and Ni-NTA biosensors) – 5-20 mM DMSO, ethanolamine, imidazole, or other solvents Some of these reagents can also be used as NSB blocking reagents. When used for blocking, these reagents can also be a cause of non-specific signal. Transferring from a baseline step in pure PBS to a step with glycerol will look like a binding curve (as glycerol slowly infiltrates the sensor surface). Conversely, when using a 1% BSA solution during a blocking step, transitioning to a step without that BSA can cause a downward trend (Figure 3) that can obscure binding events with other proteins. To prevent blocking reagents from affecting the signal, ensure that all steps before and after the analyte binding step (second baseline and dissociation) contain the same buffer composition, and that they’ve had adequate time to come to equilibrium. If additives present in the sample matrix is creating a non-specific signal, it is often easiest to perform a buffer exchange of the sample as serial dilution of the sample will also lead to serial dilution of matrix. Figure 3: Unloaded SA biosensors undergoing various buffer conditions to investigate NSB. When using 1% BSA (blocking buffer) in the prewet step, no NSB of anti-PD-1 is observed, however as BSA is not preserved in the baseline buffer and sample buffer a negative drift is present. DETERMINING THE EXTENT OF NSB To determine the extent of non-specific signal, the best approach is to obtain total binding signal without NSB blocking, then add blocking agents one at a time. Figure 4 shows a flowchart for users to identify and minimize NSB for assays with purified and crude samples respectively. Users can follow these guidelines to determine NSB in their assays and determine acceptable NSB levels. In subsequent sections, we demonstrate that incorporating an NSB blocker is a highly effective approach for suppressing unwanted binding. The general strategy for identifying and eliminating NSB is to start from the total NSB signal in a non-blocking medium such as PBS, only adding blocking agents after determining the starting NSB%. This strategy enables users to know the extent of NSB blocking impact from each element of the blocking buffer, which can help to limit the total blocking agents present in the final solution. Far too commonly, users jump immediately to very strong blocking conditions, which can lead to unusual results without knowing the efficacy of blocking that’s actually occurring. In this application note, we primarily focus on the effect of BSA, and diluted many samples 1:1 into a 2% BSA solution (resulting in a 1% BSA working concentration). Additional benefits can be also noted by diluting the sample at a greater ratio than 1:1, provided the concentration is high enough to still reliably detect ligand/analyte binding. Sometimes using too many blocking agents can affect the specific binding of certain biomolecule partners or cause unwanted data artifacts such as baseline drift. In these scenarios, it is recommended to try either a different buffer system (e.g. HBS), a different biosensor type, and/or reversing which binding partner is being immobilized onto the sensor surface. Figure 4: Flowchart for stepwise troubleshooting of sample NSB. While many users may want to begin with a mild blocking buffer (like Q buffer), it is recommended to begin with PBS in order to determine overall effectiveness of each blocking agent. Using too many or ineffective blocking agents can lead to unusual results or data artifacts. RESOLVING NSB IN CRUDE LYSATES (EXPI293 AND OTHERS) When screening and using a crude sample for ligand loading, having some media NSB to the sensor is expected, and as long as analyte binding can be detected, it does not matter much. However, when using crude samples as analytes, or when quantitating from a crude sample, blocking is essential for accurate data. Figure 5 provides an example of the typical NSB response observed when performing quantitation or kinetics where steps are in Expi293 lysate [3]. In this case, we tested the same ligand/analyte pair (biotinylated anti-PD-1 and PD-1) using a streptavidin biosensor. Increasing concentrations of BSA yielded a drastic reduction in NSB signal for Expi293 (Figure 5, bottom-left), with a 1% BSA concentration driving overall NSB below 10%. Further reduction in NSB could be achieved through combination with other blocking agents, such as Tween20 or biocytin (when using an SA biosensor). Figure 6 examines calculation of KD values using analytes in Expi293. To test whether the blocking has a dramatic effect on the intended interaction between the anti-PD-1 and PD-1 analyte, the interaction kinetics were measured in both purified samples, as well as in lysates spike-ins in Expi293, ExpiCHO and E. coli lysates (Table 1). As shown, the KD of the interactions after adequate blocking (and subtraction of baseline in the appropriate blocking solution) showed a very similar KD in each assay replicate. Figure 5 (A): Biotinylated anti-PD-1 was loaded to SA biosensor, which was bound to PD-1 spiked into Expi293 lysate. Without blocking, the various Expi293 concentrations were nearly indistinguishable. (B) Addition of BSA alone improves NSB in Expi293 cell lysate in this spike-in test. Percentages are given as final BSA values after diluting 1:1 in a higher % BSA media. 1% BSA depleted the NSB to <10%. Neither biocytin nor Tween20 were used, which could further improve results. Figure 6: Optimized binding of PD-1 spiked in Expi293 with 1% BSA blocking, removing significant NSB. Average Determined KD (nM, n=3)K Buffer16 ± 2Expi29317 ± 3ExpiCHO14 ± 4E. coli22 ± 3 Table 1: Application of effective blocking strategies yield equal KD results for the interaction of Anti-PD-1 and PD-1 comparing purified protein and spike-ins using Expi293, ExpiCHO, and E. coli lysates. CONCLUSION NSB is a common problem in BLI analysis, caused by biomolecules in a sample interacting with the biosensor components. This can even happen within purified samples, as they interact with sensor components such as the exposed glass, the neutrally-charged polysaccharide on the sensor surface, streptavidin, or other components of the biosensor. These interactions can be prevented through competition using blocking agents such as BSA, Tween20, and similar. By following the flow chart provided in Figure 4, users can generate protocols to effectively reduce and optimize for sample NSB in a variety of matrices. Download Application Note ABBREVIATIONS AbbreviationFull TermBLIBiolayer interferometryBSABovine serum albuminCVCoefficient of VariationDMSODimethyl sulfoxideE. coliEscherichia coliELISAEnzyme-Linked Immunosorbent AssayExpiCHOExpressed Chinese Hamster OvaryExpi293Expression system based on suspension-adapted human embryonic kidney (293) cellsKDEquilibrium dissociation constantNSBNon-specific bindingNTANitrilotriacetic acidPBSPhosphate-Buffered SalinePD-1Programmed cell death protein 1SAStreptavidinSDSSodium dodecyl sulfate REFERENCES AND RECOMMENDED READING Biolayer interferometry and its applications in drug discovery and developmentAna Jug, Tomaž Bratkovič and Janez IlašTrends Anal. Chem. 2024, 176, 117741https://doi.org/10.1016/j.trac.2024.117741 Suppressing nonspecific binding in biolayer interferometry experiments for weak ligand–analyte interactionsAlyssa Dubrow, Bryan Zuniga, Elias Topo, and Jae-Hyun ChoACS Omega 2022, 7 (11), 9206-9211https://doi.org/10.1021/acsomega.1c05659 Designing binding kinetic assay on the bio-layer interferometry (BLI) biosensor to characterize antibody-antigen interactions.Vishal Kamat and Ashique RafiqueAnal. Biochem. 2017, 536, 16-31https://doi.org/10.1016/j.ab.2017.08.002
Resources HIS XT Probe: Advanced His-Tag Capture for Kinetics, Quantitation, and Epitope Binning Download our new Anti-His (HIS) XT Probes Application Note and Product Note Get the Complete HIS XT Technical Documentation Why Download These?Struggling with baseline drift in His-tag assays? The HIS XT Application Note shows you how AI-designed NovoBody™ probes deliver:✓ 58% reduction in baseline drift✓ 4x higher signal resolution✓ Cleaner kinetics data for weak binders✓ Extended probe lifetime (10+ regeneration cycles)✓ Zero Fc interference Inside you’ll find:– Performance comparison data– Application protocols (kinetics, quantitation, epitope binning)– Customer validation results– Technical specifications Request Application Note Download
Resources Selection Guide: Gator Probes for His-tagged Protein Capture Find the best probe for your His-capture assay When working with His-tagged proteins, not all capture strategies are equal. Crude lysate introduces non-specific binding, some proteins have less-accessible tags, and high throughput assays demand faster binding steps and sensitivity. Gator® Bio offers three His-tag biosensor capture chemistries, each built for different assay needs. Choosing the right one depends on your sample matrix, your buffer composition, the affinity you need to resolve, and the speed required for your assay. Access the full details and recommendations by downloading the Selection Guide PDF: Download Selection Guide Recommendations based on sample characteristics Sample/Assay CharacteristicsAnti-His(PN: 160009)Ni-NTA(PN: 160016)Anti-His (HIS) XT(PN: 160050)Crude samples or complex matrices✔✔Buffers with reducing agents or chelators✔✔Picomolar affinity measurements✔Small analytes (< 15 kDa) or weak interactions✔Analysis of Fc receptor binding✔✔Sample-limited applications✔Standardized, high-throughput workflows in clean buffers✔✔Table 1: Recommended His-capture probes for common sample and assay needs The right choice usually comes down to two questions: how clean is the sample, and how sensitive does the measurement need to be. Anti-His and Anti-His XT both tolerate certain crude lysates and buffers containing reducing agents or chelators, conditions that will strip a Ni-NTA surface, because nickel-nitrilotriacetic acid coordination depends on an intact metal-chelate bond. Ni-NTA remains a strong choice for purified samples in standardized, high-throughput workflows where buffer composition is controlled. Anti-His XT is ideal for picomolar affinity work, small analytes under 15 kDa, weak interactions, and sample-limited applications where you can’t afford to use much material. Key probe features to consider FeatureAnti-His(PN: 160009)Ni-NTA(PN: 160016)Anti-His (HIS) XT(PN: 160050)Capture SurfaceMonoclonal AntibodyNi-NTA CoordinationAI-Designed NovoBody™ApplicationsQ / K / EPQ / K / EPQ / K / EPQuantitation Dynamic Range0.25 – 500 µg/ml0.1 – 1000 µg/ml0.2 – 1000 µg/mlSample RequirementsHighModerateLowCompatible Sample MatrixPurified proteinsE coli lysateCHO LysateExpi293 LysatePurified proteinsPurified proteinsE coli lysateCHO lysateRegeneration / Reuse5-10 regenerations10+ regenerations10+ regenerationsKey StrengthsSpecific His-tag recognition; compatible with many buffersSimple, widely used capture chemistry; broad dynamic rangeHigher signal response per binding event, excellent ligand affinity, low ligand use, optimized to reduce avidityTable 2: Feature comparison between Gator Bio Anti-His, Ni-NTA, and Anti-His (HIS) XT probes Anti-His ProbesAnti-His captures His-tagged protein through a monoclonal antibody surface. It handles purified protein, E. coli lysate, CHO lysate, and Expi293 lysate, and supports quantitation, kinetics, and epitope binning across a dynamic range of 0.25 to 500 µg/mL. The surface regenerates 5 to 10 times using Gator Regen Buffer (Salt) (PN: 120012), and its antibody-based recognition keeps working in buffers that would disrupt a metal-chelate surface. Ni-NTA ProbesNi-NTA uses nickel-nitrilotriacetic acid coordination to capture His-tagged protein directly, without an antibody intermediate. It’s built for purified protein in clean buffer, with a quantitation dynamic range of 0.1 to 1000 µg/mL and 10 or more regeneration cycles using Gator Ni-NTA Regen Buffer and Ni-NTA Neutral Buffer, available together as the Ni-NTA Kit. It’s a straightforward, well-established capture chemistry for labs running standardized workflows where sample purity is already controlled upstream. Anti-His (HIS) XT ProbesAnti-His XT captures His-tagged protein using an AI-designed NovoBody™. It requires the least sample input of the three chemistries, supports a 0.2 to 1000 µg/mL dynamic range, and regenerates 10 or more times using Gator Regen Buffer pH 2.0 (no salt). The higher signal response per binding event, higher affinity His-tag capture and reduced avidity make it the choice for kinetics characterization (in particular picomolar affinity work), small analytes, and assays where sample volume is limited. See more details on HIS XT performance in our Application Note. Download the full selection guide here: Download Selection Guide FAQs What’s the difference between Anti-His, Ni-NTA, and Anti-His XT biosensors? Anti-His and Anti-His XT (HIS XT) both use protein-based affinity capture surfaces that tolerate crude lysates and chelator-containing buffers. Ni-NTA captures His-tagged protein through direct metal-chelate coordination and works best with purified samples in clean, standardized buffers. Which His-tag biosensor should I use for crude lysate samples? Anti-His and Anti-His XT (HIS XT) are both built for crude samples and complex matrices, including E. coli, CHO, and Expi293 lysates (see probe-specific recommendations in Table 2). Ni-NTA is recommended for purified proteins only. Which His-tag biosensor should I use for a high throughput cell-free capture workflow? Anti-His XT (HIS XT) has the fastest ligand-loading ability and the greatest sensitivity of the three, ensuring that hits are rapidly and reliably discovered. It also has reduced baseline drift, ensuring that analyte binding kinetics are accurate. Which biosensor measures picomolar affinity interactions? Anti-His XT (HIS XT) is the chemistry built for picomolar affinity measurements, along with small analytes under 15 kDa and other weak interactions. Can His-tag biosensors be reused after regeneration? Yes. Anti-His supports 5 to 10 regeneration cycles (sample and condition dependent). Ni-NTA and Anti-His XT both support 10 or more. Which His-tag biosensor works in buffers with reducing agents or chelators? Anti-His and Anti-His XT tolerate reducing agents and chelators. Ni-NTA does not, because its capture mechanism depends on an intact nickel-chelate bond that these compounds disrupt. How much sample do I need for each His-tag biosensor? Anti-His has the highest sample requirement, Ni-NTA is moderate, and Anti-His XT requires the least input of the three, making it the choice for sample-limited applications. Get in touch Still not sure which probe fits your application? Get in touch with us at [email protected]. Shop now Find the right biosensors for your research. Explore the Gator Bio catalog and shop biosensors for your biolayer interferometry assays. Browse complete biosensor catalog